22
Rosemount Analytical,
Uniloc Division
2400 Barranca Pkwy
Irvine, CA 92606
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
REMOVE BURRS & SHARP EDGES .020 MAX
MACHINED FILLET RADII .020 MAX
FINISH
MATERIAL
PROJECT
ENGR APVD
SIZE
DWG NO.
REV
TITLE
E
P
Y
T
EL
A
CS
This document contains information proprietary to
Rosemount Analytical, and is not to be made available
to those who may compete with Rosemount Analytical.
CHECKED
DRAWN
THIS DWG CREATED IN
DATE
DESCRIPTION
BILL OF MATERIAL
QTY
ITEM
PART NO.
RELEASE DATE
ECO NO. REV
LTR
ECO
YB
N
O
I
T
PIR
C
S
E
D
DATE
REVISION
CHK
SOLID EDGE
TOLERANCES
-
+
-
+
ANGLES
-
+
.010
.XXX
.XX
.030
APPROVALS
D
1
A
B
2
3
4
5
8
7
6
8
7
6
5
4
3
2
1
A
B
C
D
C
D
1400288
A
NONE
SHEET OF
1
2
1400288
8925
A
NOMINAL SURFACE FINISH 125
5-3-04
5/6/04
Uniloc
SCHEMATIC, INSTALLATION
THIS DOCUMENT IS
CERTIFIED BY
REV
REV
REV
REV
REV
REV
REVISIONS NOT PERMITTED
W/O AGENCY APPROVAL
B. JOHNSON
J. FLOCK
5-6-04
5081-P-FI XMTR CSA
PH
SENSOR
WITH
TC
UNSPECIFIED
POWER SUPPLY
17.5 VDC MAX
MODEL
5081-P-FI
XMTR
MODEL
5081-P-FI
XMTR
MODEL
5081-P-FI
XMTR
MODEL
5081-P-FI
XMTR
INFRARED RED
REMOTE CONTROL UNIT
(RMT PN 23572-00)
FOR USE IN
CLASS I AREA ONLY
+PH
SENSOR
PREAMP
(NOTE 3)
+PH
SENSOR
TB1-
4
5
7
10
PREAMP
(NOTE 3)
+PH
SENSOR
WARNING-
WARNING-
12
3
4
5
6
7
8
9
10
11
12
13
14
15
16
12
3
4
5
6
7
8
9
10
11
12
13
14
15
16
12
3
4
5
6
7
8
9
10
11
12
13
14
15
16
12
3
4
5
6
7
8
9
10
11
12
13
14
15
16
TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES,
DISCONNECT POWER BEFORE SERVICING.
UNCLASSIFIED AREA
SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY OR
SUITABILITY FOR DIVISION 2.
RECOMMENDED CABLE
4 WIRES SHIELDED
22 AWG. SEE NOTE 1
RECOMMENDED CABLE
PN 9200273 (UNPREPPED)
PN 23646-01 PREPPED
10 COND, 2 SHIELDS 24 AWG
SEE NOTE 1
CSA APPROVED PREAMP
THAT MEETS REQUIREMENTS
OF NOTE 2
CSA APPROVED PREAMP
THAT MEETS REQUIREMENTS
OF NOTE 2
IS CLASS I, GRPS A-D
CLASS II, GRPS E-G
CLASS III
NI CLASS I, DIV 2
GRPS A-D
CLASS II, DIV 2
GRPS E-G
HAZARDOUS AREA
CSA INTRINSIC SAFETY INSTALLATION
CSA APPROVED
ASSOCIATED APPARATUS
SUITABLE FOR FISCO
SEE NOTE 8 AND TABLE III
UNSPECIFIED
POWER SUPPLY
17.5 VDC MAX
CSA APPROVED
ASSOCIATED APPARATUS
SUITABLE FOR FISCO
SEE NOTE 8 AND TABLE III
UNSPECIFIED
POWER SUPPLY
17.5 VDC MAX
CSA APPROVED
ASSOCIATED APPARATUS
SUITABLE FOR FISCO
SEE NOTE 8 AND TABLE III
UNSPECIFIED
POWER SUPPLY
17.5 VDC MAX
CSA APPROVED
ASSOCIATED APPARATUS
SUITABLE FOR FISCO
SEE NOTE 8 AND TABLE III
NOTES: UNLESS OTHERWISE SPECIFICED
NOTES ON SHEET 2 OF 2
FISCO
J. FLOCK
5/6/04
CSA
A