INSTALLATION
PROCEDURES
Installation consists of mounting the transmitter and conduit and making
electrical connections. Procedures follow for each operation.
Mechanical Transmitter
The threaded interface between the sensor module and the electronics
housing is hermetically sealed before shipment. The integrity of this seal is
necessary for the safe operation of the transmitter during accident conditions.
If the seal is broken, reseal it according to “Connecting the Electrical Housing
to the Sensor Module” on page 5-7.
1. Mount the bracket to a panel or other flat surface as shown in
Figure 2-4. Use four
3
/8-in. diameter bolts (not supplied with unit). SAE
grade 2 bolts were used during qualification testing. Torque each bolt
to 19 ft-lb (26 N-m).
2. Attach the transmitter to the mounting bracket, as shown in
Figure 2-4. Use four
7
/16-20 ϫ
3
/4 bolts with washers (supplied with
unit). Torque each bolt to 21 ft-lb (29 N-m).
Figure 2-4. Typical Transmitter Mounting Bracket Configuration.
Be careful not to break the neck seal between the sensor module and the
electronics housing.
1.8
(45.7)
2.3
(58)
Center of Gravity
(Includes Bracket)
ACCEPTABLE ALTERNATE
MOUNTING
PANEL MOUNTING HOLE
PATTERN
(BACK SIDE)
MOUNTING BRACKET FOR PANEL
MOUNT SHOWN IN TYPICAL
MOUNTING CONFIGURATION
10 (254)
Minimum
Clearance
2.75
(69.9)
3
/8-in.
Bolts (4)
(Customer
Supplied)
4.93
(125)
1.2
(30)
2.3
(58)
Center of Gravity
(Includes Bracket)
5
(127)
2.81
(71.4)
NOTE
Dimensions are nominal in inches (millimeters).
NOTES
1. Orientation with respect to gravity is not critical.
2. Units can alternately be mounted with process
connection adjacent to bracket.
2.81 (71.4)