Electro-Voice NetMax N8000 Stereo Receiver User Manual


 
Control Elements and Connections
13
NetMax N8000 System Controller
Owner’s manual
N8000 automatically detects an installed network module. The module can be configured in the
PC software IRIS-Net.
ETHERNET Interface
A computer and/or other N8000 devices can be connected
via the Ethernet interface for 100Base-TX / 10Base-T
Ethernet networks. Normally this connection is established
via a standard (straight throug) Ethernet cable and an
Ethernet hub or a switch. If the N8000 is to be connected
directly with a computer or another N8000, a crossed Ethernet cable (crossover cable) must be
used.
RS-232 Interfaces
The N8000 can be connected to external devices, such as
multimedia system (AMX™, Crestron™) or facility
management systems via the two RS-232 interfaces. All
N8000 functions and parameters can be controlled and
monitored via RS-232. Communication is done using an
ASCII parser which is easy to implement. Thus, a NetMax
system can be easily combined with media and touch panel
control systems. A PC can also be connected to the RS-232
port to access N8000 parameters using a terminal program
like Hyperterminal. A special instruction set is available in order to establish a connection to a
PROMATRIX/PROANNOUNCE system. The two RS-232 ports can be configured according to
their corresponding application via the IRIS-Net PC software.
REMOTE CAN BUS
Electro-Voice remote amplifiers and other devices with CAN
interfaces can be connected to the N8000 via the CAN
interface. Up to 100 remote amplifiers can be connected
with a single N8000. All connected components are linked to
the NetMax monitoring and control platform.
The STATUS-LED is provided to monitor the communication
on the CAN bus. If the CAN interface is not in use, the LED
is deactivated. In normal mode the LED flashes every 2
ATTENTION:
The N8000 has to be switched off if you want to change or install a module. You will find
detailed instructions in the data sheet of the corresponding module.