7.2 Troubleshooting
The AR-32 Architectural Recorder System should perform well when properly operated and maintained,
however, sometimes things just don’t work like they should. Table 5 contains symptoms, causes, and resolutions
for common faults.
Table 5
Symptom Cause Resolution
No Power Bad power connection. Check power connection.
Reconnect plug if needed.
No receptacle power. Ensure receptacle has power.
Bad fuse. Check fuse. Replace if needed.
Erratic Fixture
Behavior
Improper DMX addressing. Check and correct DMX
addressing.
Improper DMX data cable. Verify proper DMX data cable.
Replace if needed.
No DMX termination. Properly terminate DMX data run.
No Control Bad data connection. Check all data cable connections.
Repair or reconnect as needed.
No power. See No Power above.
Bad remote batteries. Replace remote batteries.
Improper DMX addressing. Check and correct DMX
addressing.
32