8
ENGLISH
6
The detected speakers are displayed.
Next
Retry
[ENT]:Next
Front Sp. :Yes
Center Sp. :Yes
Subwoofer :Yes
Surround Sp. :Yes
Step1:Speaker Detection
MultEQ
NOTE
If a connected speaker is not displayed, the
speaker may not be connected correctly. Check
the speaker connection.
7
Use ui to select “Next” and then
press ENTER.
8
Move the setup microphone to
position 2, use ui to select “Next”,
and then press ENTER.
The measurement of the second position
starts. Measurements can be made in up to
six positions.
Step2:Measurement
MultEQ
Please place microphone
Cancel
[ENT]:Next
Next
Calculate
2nd listening position.
at ear height at
If you want to omit measurements from the next
position onward, select “Calculate”.
(Go to
Step 3 Calculating
)
9
Repeat step 8, measuring positions 3
to 6.
When measurement of position 6 is
completed, a “All the measurements were
finished.” message is displayed.
Step2:Measurement
MultEQ
Retry
Cancel
[ENT]:Calculate
Calculate
All the measurements
were finished.
Set up speakers (Audyssey
®
Auto Setup)
Preparation
3
Set up
the remote control unit
n Set up the operation mode
Press AMP to set the remote control
unit to amplier operation mode.
Press AMP
4
Connect the setup microphone to the
SETUP MIC jack of this unit.
3-1.Audyssey Auto Setup
MultEQ
at ear height at
Normal
Pre Assign:
Start
Cancel
[ENT]:Select [RTN]:Back
Please place microphone
main listening position.
When the setup microphone is
connected, the following screen is
displayed.
Here, we explain setup using the example of
5.1-channel speaker playback.
For setting other than 5.1-channel surround,
select “Pre Assign” and perform steps 3 to 4 of
“Set up speakers” (vpage29).
5
Use ui to select “Start” and then
press ENTER.
When measuring begins, a test tone is
output from each speaker.
• Measuring requires several minutes.
If “Cancel” is selected
“Cancel Auto Setup?” is displayed on the TV
screen. If “Yes” is selected, “Audyssey Auto
Setup” closes.
NOTE
If “Caution” is displayed:
Go to “Error messages” (vpage 10), check
any related items, and perform the necessary
procedures.
If the problem is resolved, return and restart
“Audyssey Auto Setup”.
When performing Audyssey Auto
Setup over again
Press ui to select “Retry”, and then press
ENTER.
When measuring has stopped
q Press ui to select “Cancel”, then press
ENTER.
w Press o p to select “Yes”, then press ENTER.
Setting up the speakers again
Repeat the operation from step 4 of
Preparation
.
Remote control operation
buttons
Move the cursor
(Up/Down/Left/Right)
Confirm the setting Return to previous menu
Step 1
Speaker Detection
Step 2
Measurement