OPERATING INSTRUCTIONS
Setup
SETTING UP THE SYSTEM
1) Place the DMX-40B on a level surface. Note! The DMX-40B can also be rack mounted,
occupying three rack spaces (3U).
2) Plug the AC to DC power supply into the system back panel and into the mains outlet.
3) Plug in your DMX cable(s) to your intelligent lighting as described in the respective fixture’s
manual. For a quick overview of DMX see the “DMX Primer” on page 18.
4) Reset the system using the instructions below.
RESETTING THE SYSTEM
Warning: this will reset the controller to its factory defaults. This will erase all programs and settings.
1) Turn off the unit.
2) Press and hold BANK UP and AUTO/DEL.
3) Turn on power to the unit (while still holding BANK UP and AUTO/DEL).
FIXTURE ADDRESSING
The DMX-40B is programmed to control 16 channels of DMX per fixture. Therefore, the fixtures you
wish to control with the corresponding “SCANNER” buttons on the unit must be spaced 16 channels
apart (check the respective fixture’s manual for how to enter the information into the fixture).
Note: failure to use these DMX assignments may cause a lack of control of the fixtures.
F
IXTURE OR
SCANNER #
D
EFAULT DMX STARTING
ADDRESSҏ
B
INARY DIPSWITCH SETTINGS
S
WITCH TO THE “ON POSITION”
11 1
217 1,5
333 1,6
4 49 1,5,6
565 1,7
6 81 1,5,7
7 97 1,6,7
8 113 1,5,6,7
9 129 1,8
10 145 1,5,8
11 161 1,6,8
12 177 1,5,6,8
DMX-40B User Manual 8 Revised: 2006-12-06 09:36:47