Behringer Q1204USB Stereo Receiver User Manual


 
behringer.com
14 XENYX 1204USB/X1204USB User Manual
EQ mono channels
Low 80 Hz / ±15 dB
Mid 2.5 kHz / ±15 dB
High 12 kHz / ±15 dB
EQ stereo channels
Low 80 Hz / ±15 dB
Mid 2.5 kHz / ±15 dB
High 12 kHz / ±15 dB
Aux sends
Type ¼" TS connector, unbalanced
Impedance approx. 120 Ω
Max. output level +22 dBu
Stereo aux returns
Type ¼" TRS connector,
electronically balanced
Impedance approx. 20 kΩ bal. / 10 kΩ unbal.
Max. input level +22 dBu
Main outputs
Type XLR, electronically balanced
Impedance approx. 240 Ω bal. / 120 Ω unbal.
Max. output level +28 dBu
Control room outputs
Type ¼" TS connector, unbal.
Impedance approx. 120 Ω
Max. output level +22 dBu
Headphones output
Type ¼" TRS connector, unbalanced
Max. output level +19 dBu / 150 Ω (+25 dBm)
DSP 24-bit Texas Instruments
TM
Converter 24-bit Sigma-Delta,
64/128-times oversampling
Sampling rate 40 kHz
USB
Audio Stereo In/Out
Connector TypeB
Converter 16-bit
Sample Rate 48 kHz
Main mix system data
2
Noise
Main mix @ -oo, Channel fader -oo -105 dB / -108 dB A-weighted
Main mix @ 0 dB, Channel fader -oo -95 dB / -97 dB A-weighted
Main Mix @ 0 dB, Channel fader @ 0 dB -82,5 dB / -85 dB A-weighted
Power supply
Mains voltage 100 - 240 V~, 50/60 Hz
Power consumption 40 W
Fuse 100 - 240 V~: T 1.6 A H 250 V
Mains connection Standard IEC receptacle
Physical
1204USB
Dimensions (H x W x D) approx. 3 ⁄ x 9 ⁄ x 13"
approx. 97 x 247 x 328 mm
Weight (net) approx. 5 ⁄ lbs / 2.56 kg
X1204USB
Dimensions (H x W x D) approx. 3 ⁄ x 9 ⁄ x 13 ⁄"
approx. 97 x 247 x 334 mm
Weight (net) approx. 5 ¾ lbs / 2.60 kg
Measuring conditions:
1: 1 kHz rel. to 0 dBu; 20 Hz - 20 kHz; line input; main output; unity gain.
2: 20 Hz - 20kHz; measured at main output. Channels 1 - 4 unity gain; EQ flat; all channels on main mix;
channels 1/3 as far left as possible, channels 2/4 as far right as possible. Reference = +6 dBu.
BEHRINGER is constantly striving to manintain the highest professional standards. As a result of these efforts,
modifications may be made from time to time to existing products without prior notice. Specifications and
appearance may differ from those listed or illustrated.