Asus P4GD1 Radio User Manual


 
5-225-22
5-225-22
5-22
Chapter 5: Software supportChapter 5: Software support
Chapter 5: Software supportChapter 5: Software support
Chapter 5: Software support
IT8212 Setup Utility (C)Copyright 2002-2004 ITE, Inc.
[ Rebuild RAID Menu ]
Array No Array Mode Drive No Size(MB) Status
Array 0 Stripe 4 XXXXXX Functional
Array 1 Mirror 2 XXXX Functional
Array 2 ---- ---- ----- -----
Array 3 ---- ---- ----- -----
: Capacity (GB) : Bootable Array
[] Up [] Down [Enter] Select [ESC] Exit
Rebuilding a RAID arrayRebuilding a RAID array
Rebuilding a RAID arrayRebuilding a RAID array
Rebuilding a RAID array
This option allows you to reconstruct an existing RAID array. This option
applies only to RAID1 (Mirrored) or RAID 0+1(Striped+Mirrored) sets.
To rebuild a RAID array:
1. From the IT8212 Setup Utility screen, press <4>. The following screen
appears.
2. Use the up or down arrow keys to select a RAID array, then press
<Enter> to rebuild. The following screen appears.
IT8212 Setup Utility (C)Copyright 2002-2004 ITE, Inc.
[ Source Drive ]
[ Target Drive ]
Channel ID Drive Name Size (MB)
Pri/D1 XXXXXXXXXX XXXXX
: Capacity (GB)
[] Up [] Down [Enter] Select [ESC] Exit
[ Drive List]
Channel ID Drive Name Size (MB)
Sec/D1 XXXXXXXXXX XXXXX
Channel ID Drive Name Size (MB)
Pri/D1 XXXXXXXXXX XXXXX
Sec/D1 XXXXXXXXXX XXXXXX