Allied Telesis 86253-07 Speaker User Manual


 
Patch 86253-07 For Rapier Series Switches 5
Patch 86253-07 for Software Release 2.5.3
C613-10382-00 REV E
Entering “?” after a command at the CLI gives context-sensitive Help about
parameters valid for the command. Occasionally, commands (for example,
ENABLE IP MULTICASTING) were executed when “?” was entered at the
end of the command. This issue has been resolved.
Executing the SHOW DEBUG command caused a fatal error if the
temporary log had been destroyed with the DESTROY LOG
OUTPUT=TEMPORARY command. This issue has been resolved.
When an interface-based enhanced NAT was defined in a firewall policy,
and a reverse NAT rule was defined to redirect traffic to a proxy server, the
reverse NAT did not work correctly. The proxy server did not receive any
traffic from the device. This issue has been resolved.
When the device operated in NTP Client mode, the SHOW TIME command
sometimes displayed the incorrect time. This issue has been resolved.
The device sometimes rebooted when OSPF on demand was enabled for
PPP. This issue has been resolved.
When a port’s ingress limit was set to less than 1000 with the
INGRESSLIMIT parameter in the SET SWITCH PORT command, sending
packets to a tagged port caused FCS errors on transmission. This issue has
been resolved.
The timeout interval for IGMP group membership now conforms to RFC
2236 for IGMPv2.
After a Summary LSA for the default route in a stub area had been refreshed
by an Area Border Router, and the Area Border Router was restarted, the
Summary LSA was not advertised into the stub area again. This issue has
been resolved.
PCR: 31270 Module: CURE, IPG, ATK,
DVMRP, IPX2, LB, LOG, SNMP,
UTILITY
Level: 3
PCR: 40006 Module: LOG Level: 2
PCR: 40007 Module: FIREWALL Level: 2
PCR: 40008 Module: NTP Level: 3
PCR: 40012 Module: IPG, OSPF Level: 2
PCR: 40020 Module: SW56 Level: 3
PCR: 40023 Module: IPG Level: 2
PCR: 40038 Module: OSPF Level: 2