54
GENERAL MAINTENANCE
9. To reinstall the burners, reverse steps 3 through 8.
ƽCAUTION:The burner openings(1) must be
positioned properly over the valve orifices(2).
Check proper assembly before fastening manifold in
place.
Crossover
®
Ignition System Operations
If the Crossover Ignition System fails to ignite the Left
burner in a heat zone, light the Left burner with a
match. If the Left burner lights with a match, then
check the Crossover Ignition System.
• Check that both ignition wires are attached
properly.
• Check that the Crossover Ignition button is
activating
• Replace battery with a like brand.
• You should hear the igniter sparking.
If the Crossover Ignition System still fails to light,
Contact Customer Service toll free at 1 (866)
VIELUXE.
ƽWARNING: After reinstalling the gas lines, they
should be leaked-checked with soap and water
solution before using the barbecue. (See Step
“Check for gas leaks.”)