A SERVICE OF

logo

52
GENERAL MAINTENANCE
Replacing Main Burners
1. Your Vieluxe Gas Barbecue must be OFF and
cool.
2. Turn OFF gas at source.
3. Disconnect regulator.
4. Remove cooking grates.
4. Remove Flavorizer bars.
5. To remove control panel refer to Remove the
control panel under Check for Gas Leaks on
page 49.
6. Remove the manifold: Remove bolts from
manifold brackets. Pull manifold out from burner
tubes leaving flexible connections on right side in
place.
Main Burner Flame Pattern
The Vieluxe
TM
Gas Barbecue burners have been factory
set for the correct air and gas mixture. The correct
flame pattern is shown.
1) Burner tube
2) Tips occasionally flicker yellow
3) Light blue
4) Dark blue
If the flames do not appear to be uniform throughout
the burner tube, follow the burner cleaning procedures.
Main Burner Cleaning Procedure
Turn off the gas supply. Remove the manifold.
Look inside each burner with a torch.
Clean the inside of the burners with a wire (a
straightened-out coat hanger will work). Check and
clean the air shutter opening at the ends of the
burners. Check and clean the valve orifices at the
base of the valves. Use a brass bristle brush to clean
outside of burners. This is to make sure all the burner
ports are fully open.
ƽCAUTION: Do not enlarge the burner ports when
cleaning.
(2)
(3)
(4)
(1)
Vieluxe - 44 inch