Reference manual Foundation Fieldbus Control module
DOC.RM.QC34.E Rev: A
October, 2006
Index
No.
Name Description Valid Range Initial Value Permission
9 TRANSDUCER_DIRECTORY Array containing the transducer definitions (empty) 0,0 0,0 Read only
10 TRANSDUCER_TYPE Identifies the type of Transducer Block. Standard
discrete
positioner
Standard
discrete
positioner
Read only
11 XD_ERROR Extensions to Block Error indicated by the “Other” bit 0
being set (enumaration)
0 = no error 0 = no error Read only
16: unspecified error
17: General error (not used)
18: Calibration error
19: configuration error (not used)
20: Electronics failure
21: Mechanical failure (not used)
22: I/O Failure
23: Data Integrety error (not used)
24: Software error
25: Algorithm error (not used)
12 COLLECTION_DIRECTORY A directory that specifies the number, starting indices,
and DD Item IDs of the data collections in each
transducer within a Transducer Block.
0 0 Read only
13 FINAL_VALUE_D States the requested valve position and status written by
a discrete function block (set point)
2 Read only
STATUS Read only
VALUE requested position 0: close, 1: open 0 to 1 0 Read only
14 ACT_FAIL_ACTION Defined by Foundation Fieldbus,
has no effect on our
device!
0: undefined (DA), 1 Self-closing(SA), 2 Self opening(SA)
0 to 3 0 Read / Write
15 ACT_MAN_ID Actuator manufacturer ID in Foundation Mfg id units.
Is: Emerson Process Management Valve Automation
Division
0x564144 0x564144 Read only
16 ACT_MODEL_NUM Actuator model number. Depends where it is mounted.
Can be set by customer.
all spaces Read / Write
17 ACT_SN Seriel number of actuator.
Can be set by customer.
all spaces Read / Write
18 VALVE_MAN_ID Valve manufacturer ID in Foundation Mfg id units.
Can be set by customer.
0 Read / Write
19 VALVE_MODEL_NUM Indicates available function block execution routines all spaces Read / Write
20 VALVE_SN Seriel number of valve.
Can be set by customer.
all spaces Read / Write
21 VALVE_TYPE Type of valve. Can be set by customer, but it is not used
by the device.
0: undefined, 1: Sliding stem, 2: Rotary
0 to 2 2 Read / Write
22 XD_CAL_LOC The location where device was last initialized.
Can be set by customer,
all spaces Read / Write
23 XD_CAL_DATE The date the unit was calibrated/initialized.
Can be set by customer.
Read / Write
24 XD_CAL_WHO Person who did the calibration.
Can be set by customer.
all spaces Read / Write
Table 4.2 FieldQ™ Transducer Block (continued)
General Transducer Block parameters (continued)