Yorkville Sound CA1 Stereo Amplifier User Manual


 
7
nominalpowerforzones1-4.Whenusingazoneselectorlow-impedancespeakers
cannotbeused,defaultisconstantvoltage70Voutput.
19. Output Terminal Strip
These5terminalsallowconnectingspeakers.
20. PRE OUT Terminal Strip
Thisterminalstripoutputsthemixedaudiosignalsofallsources(thatareconnected
COM 25V 70V 100V
DC 24V 15A
+
-
4
24Vdc
COM
0 70V
COM COM Zone 4 Zone 3 Zone 2 Zone 1
0 70V 0 70V 0 70V
Connecting the speakers to 70V output
COM 25V 70V 100V
DC 24V 15A
+
-
4
4-ohms
Connecting the speakers to 4-ohm output
COM 25V 70V 100V
DC 24V 15A
+
-
4
8-ohms
Total Impedance 4-ohms
8-ohms