Sony STR-DA3100ES Stereo Receiver User Manual


 
Additional Information
masterpage:Right
lename[E:\SEM_Janet\Revision_DA3100ES\J9050000_2514877121STRDA3100ESU\251487
121\GB010ADD_STR-DA3100ES-U.fm]
model name1[STR-DA3100ES]
[2-514-877-12(1)]
75
US
Remote control
The remote does not function.
Point the remote at the remote sensor on the
receiver.
Remove any obstacles in the path between the
remote and the receiver.
Replace all the batteries in the remote with new
ones, if they are weak.
Check if the command modes of the receiver and
the remote is the same. If the command mode of
the receiver and the remote is different, you
cannot operate the receiver with the remote.
To switch the command mode of the receiver,
press ?/1 while pressing INPUT MODE. Each
time you press ?/1, the command mode switches
between “COMMAND MODE [AV2]” and
“COMMAND MODE [AV1]”. (The initial setting
is “COMMAND MODE [AV2]”.) To switch the
command mode of the remote, see “Selecting the
command mode of the remote” on page 61.
Make sure you select the correct input on the
remote.
Error messages
If there is a malfunction, the display shows a
code of two numbers and a message. You can
check the condition of the system by the
message. Refer to the following table to solve
the problem. If any problem persists, consult
your nearest Sony dealer.
DECODE ERROR/CHECK CODE 01
Appears when the signal which the receiver cannot
decode (ex. DTS-CD) is input when “DEC.
PRIORITY” in the CUSTOMIZE menu is set to
“PCM”. Set to “AUTO”.
PROTECTOR/CHECK CODE 11
Irregular current is output from the speakers. The
receiver will automatically turn off after a few
seconds. Check the speaker connection and turn on
the power again. If this problem persists, turn off the
receiver and consult your nearest Sony dealer.
Reference sections for clearing
the memory
AUDIO POWER SPECIFICATIONS
POWER OUTPUT AND TOTAL HARMONIC
DISTORTION:
(Models of area code U only)
With 8 ohm loads, both channels driven, from 20
– 20,000 Hz; rated 120 watts per channel
minimum RMS power, with no more than
0.05% total harmonic distortion from 250
milliwatts to rated output.
Amplifier section
POWER OUTPUT
Rated Power Output at Stereo Mode
1)
(8 ohms 20 Hz – 20 kHz, THD 0.05%)
120 W + 120 W
(4 ohms 20 Hz – 20 kHz, THD 0.09%)
100 W + 100 W
Reference Power Output
1)
(8 ohms 20 Hz – 20 kHz, THD 0.05%)
FRONT
2)
: 120 W + 120 W
CENTER
2)
: 120 W
SURR
2)
: 120 W + 120 W
SURR BACK
2)
: 120 W + 120 W
(4 ohms 20 Hz – 20 kHz, THD 0.09%)
FRONT
2)
: 100 W + 100 W
CENTER
2)
: 100 W
SURR
2)
: 100 W + 100 W
SURR BACK
2)
: 100 W + 100 W
1) Measured under the following conditions:
120 V AC, 60 Hz
2) Depending on the sound field settings and the
source, there may be no sound output.
Frequency response
To clear See
All memorized settings page 19
Customized sound fields page 40
Specifications
PHONO RIAA equalization curve
±0.5 dB
MULTI CH IN,
SA-CD/CD, TAPE,
MD/DAT, DVD,
TV/SAT, VIDEO 1, 2, 3
10 Hz – 100 kHz +0.5/
-2 dB (When MULTI CH
IN DIRECT and
ANALOG DIRECT is
activated)
continued