Sony MDS-JD320 MiniDisc Player User Manual


 
— 16 —
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1. PRECAUTIONS FOR CHECKING LASER
DIODE EMISSINON
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
5-2. PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-260A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connecting
the connector, be careful not to remove the solder. Also take adequate
measures to prevent damage by static electricity. Handle the flexible
board with care as it breaks easily.
pick-up
flexible board
laser tap
1.Temperature
compensation
offset adjustment
2. Laser power
adjustment
3. Traverse
adjustment
4. Focus bias
adjustment
5. Error rate check
Optical
Pick-up
IC101, IC121, IC192D101IC171
¬
¬
¬
¬
¬
G
¬
¬
¬
¬
¬
G
G
G
G
¬
¬
¬
¬
¬
BD Board
5-3. PRECAUTIONS FOR ADJUSTMENTS
1) When replacing the following parts, perform the adjustments
and checks with ¬ in the order shown in the following table.
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3) Perform the adjustments in the order shown.
4) Use the following tools and measuring devices.
Check Disc (MD) TDYS-1
(Parts No. 4-963-646-01)
Laser power meter LPM-8001 (Parts No. J-2501-046-A)
Oscilloscope (Measure after performing CAL of prove.)
Digital voltmeter
Thermometer
Jig for checking BD board waveform
(Parts No. : J-2501-124-A)
5) When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited.)
6) Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Note on page 4.)
Note :When performing laser power checks and adjustment
(electrical adjustment), use of the new MD laser power meter
8010S (J-2501-145-A) instead of the conventional laser power
meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of the pick-up.
5-4. CREATING CONTINUOUSLY RECORDED DISC
This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording disc.
1. Insert a disc (blank disc) commercially available.
2. Rotate the AMS knob and display “CREC MODE”.
3. Press the YES button again to display “CREC MID”.
Display “CREC (0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the EDIT/NO button and stop recording .
6. Press the §EJECT button and remove the disc.
The above has been how to create a continuous recorded data for the
focus bias adjustment and error rate check.
Note :
Be careful not to apply vibration during continuous recording.
Optical pick-up flexible board