Samson 131 Stereo Equalizer User Manual


 
SETTING UP THE S curve 131
7
7. Press the front panel Power switch in order to turn on the S curve 131. Press the Bypass switches
in to activate the equalizer. Note that audio signal will be muted for approximately five seconds until
the relay power-on circuitry is activated (at which time you’ll hear a click and the audio signal will be
unmuted).
8. Apply an input signal to the S curve 131 (if sending signal from a mixer output bus, drive the mixer’s
output meters at approximately 0 VU). While the input signal is present, slowly raise the front panel
mainlevel slider to it’s center detented “0” point. For best signal-to-noise ratio, the main level slider
should be at or near the “0” point during normal operation. However, if the output signal is weak, use
themain level slider to slightly boost the volume (to a maximum of 6 dB). Conversely, if the signal caus-
es the front panel +18 LEDs to light, use the main level slider to attenuate volume as necessary. In
normal operation, the +18 LED should not light at all; if they do, use the main level slider to lower the
volume of the output signal so that it does not light at all (clipping not only sounds awful, it can also
damage speakers!).
9. Experiment by moving each of the Equalizer sliders up and down, carefully listening to the audible
result on the audio signal. Bear in mind that the very lowest and highest frequency areas may have lit-
tle or no effect on some signals. If there is significant low frequency noise (rumble) in the signal,
engage the Low Cut switch. Starting with the Low Cut frequency control fully counter-clockwise, adjust
the control so that the rumble is eliminated but the bass content of the signal still remains. Some exper-
imentation with this control may be necessary to acheive a satisfying result.As you work with the vari-
ous front panel controls, press the front panel Bypass switch in and out from time to time in order to
compare the effect of the equalization curve you are creating with the original input signal.
10. Once you’ve created the frequency curve required for your particular application (see the “About
Equalization” section on the following pages for more information), an optional locking security cover
(available from your local Samson dealer) can be placed over the front panel to make sure that your
settings are not inadvertently altered.
If you have followed all the steps above and are experiencing difficulties with any aspect of setting up
or using your S curve 131, you can call Samson Technical Support (1-800-372-6766) between 9 AM
and 5 PM EST, or contact your local distributor.