46
INSTALLER
FIRMWARE UPDATES
CAV6.6 Firmware Update Procedure
Note: When a firmware update is released, it is
available online at the Document Center on
www.russound.com, in Technical Documents
under Multi-zone products. The firmware update
procedure may be modified, so always check for
the latest version.
Note: Disconnect ALL RNET links in the system
before proceeding with keypad update.
Requirements:
1. PC computer running Windows 95, 98, ME, NT,
2000, XP operating system
2. Available DB9 serial RS-232 data port
(baud rate= 38400, data bits = 8,
no parity, 1 stop bit, no flow control)
3. DB9 serial cable (male to female extension)
4. Flash Magic - Philips IC update application
(Flash Magic can be downloaded for free at:
http://www
.esacademy.com/software/flashmagic/flas
hmagic.exe)
Note: the same A/C power circuit should be
used for the system and the PC. Otherwise a
ground loop may affect proper data transfer.
Update Procedure:
Remove cover lens from CAV6.6 front panel.
Remove the “Russound” program selector switch
cover with a small flat blade screwdriver.
Connect the DB9 serial cable between the PC COM
port and one of the DB9 ports found on the front and
rear panels of the CAV6.6. Make sure the front/rear
selector switch is in the corresponding position (front
or rear).
Set the OS Program selector switch to AUX or Main to
update. The hex file will be labeled AUX or Main; set
the switch to match which file is being used.
Note: Most updates will require both processors
to be updated - the AUX should be updated first.
Press and release the Reset button next to the OS
Program selector switch, or cycle the power off and
then on for the CAV6.6.
Start the Flash Magic application. If error messages
appear, they are typically generated due to communi-
cation problems. Verify all connections,close Flash
Magic, cycle power and restart Flash Magic.
Flash Magic Required Settings:
Section 1:
COM Port: = COM port connected to on PC
Baud Rate: = 38400
Device: = XA-G49
Oscillator Freq. {MHz}: = 12.288
Section 2:
“Erase blocks 0-4” should be highlighted
Note: If there is no firmware loaded in the
CAV6.6, check “Erase all Flash + Security.” Also
un-check “Set Security Bit 1-3” found in Sect. 4.
These steps should NOT be performed if you are
updating from previous firmware version.
Section 3:
Click “Browse” button to select the new .hex file to be
used.
Note: Make sure the proper hex file is selected
(Main or AUX). Loading the wrong file will lock up
the unit)
Section 4:
No boxes should be checked.
BEFORE START, press and release the Reset but-
ton next to the OS Program selector switch, or
cycle the power off and then on for the CAV6.6.
Section 5:
Click the “Start” button to begin firmware update. The
status is shown at the bottom of the window.
Completion:
Disconnect the Programming Cable from the controller
and the PC.
Re-position the OS Program selector switch to “Run.”
Reconnect all RNET links.
Press and release the Reset button, or cycle main
power off and on to the CAV6.6 and all RNET-enabled
components in the system.