Russound CAM6.6 Stereo Receiver User Manual


 
61
e. All Other Selections: Procedure advances to DEVICE CODE (step 8)
8. DEVICE CODE Source component code for IR control.
(DevCd)
9. KEY FUNCTION (f) – Select Keypad function.
(KeyFn)
10. SAVE CHANGES? (f) Select “yes” to save the changes.
(Save?)
LEARN IR (LrnIR)
This procedure allows IR commands to be learned into the system and be centrally stored in the main
controller to let the system access the same IR codes that operate the source equipment.
NOTE: IR codes must be learned in by pointing the remote at the CAM6.6’s REAR panel IR receiver
only.
See Learn IR - Flow Chart on page 74
1. LEARNED SRC – Select the source (Source 1-6 and Miscellaneous Learned IR
(LnSrc) (Misc)) whose commands will be learned into the controller.
2. KEY FUNCTION Select the function to be learned or deleted.
(KeyFn)
3. LEARN/DELETE Select Learn IR Now or Delete IR. If Learn IR Now, a “USE
(Ln/Dl) REMOTE” prompt appears. Point the learning remote at the
controller’s IR window. If Delete IR, procedure returns to
LEARNED SRC (step 1)
4. TEST IR? If “yes,” sends the learned command to the source component
(TstIR) to test the IR. If the component responds, the IR test was a
success. If the component does not respond the Code was not
learned properly. If “no,” menu goes back to LEARNED SRC
(step 1)
5. SUCCESS? - Asks if the IR test was a success
(OK?)
IF YES - If the test was a success, specify “yes” and proceed to
KEY FUNCTION (step 2)
IF NO - If the test was a failure, specify “no” and LEARN/DELETE
(step 3) reappears on the display allowing another code to be
learned in.
INSTALLER
INSTALLATION MENU