Option Link Settings
Reference Function Fitted Alternative (Removed) Related To
R67 Application
board interface
Use IO3 of application board
interface
Use UD of application board
interface
R78
R78 Application
board interface
Use UD of application board
interface
Use IO3 of application board
interface
R67
R82 Application
board interface
Use IO2 of application user interface
Use TxD0 for onboard RS232
module
R70
R70 Application
board interface
Use TxD0 of for onboard RS232
module
Use IO2 of application user
interface
R82
R76 Application
board interface
Use IO1 of application board
interface
Use RxD0 for onboard RS232
module
R59
R59 Application
board interface
Use RxD0 for onboard RS232
module
Use IO1 of application board
interface
R76
R79 Application
board interface
Use IO0 of application board
interface
Use CLK0 for onboard RS232
module
R66
R66 Application
board interface
Use CLK0 for onboard RS232
module
Use IO0 of application board
interface
R79
R54 Application
board interface
Use WDTOVF of application board
interface
Use TDO of E10A debugger
interface
R123
R123 Application
board interface
Use TDO of E10A debugger
interface
Use WDTOVF of application
board interface
R54
Table 6-6: Application board interface links.
Table 6-7 below describes the function of the option links associated with E8 and E10A debuggers. The default configuration is indicated
by BOLD text.
Option Link Settings
Reference Function Fitted Alternative (Removed) Related To
R4 E8
Enables E8
R132 E10A Enables E10A, also can be enabled
by fitting J15.
E10A is disabled, can be
enabled if J15 is set.
E10A_EN (J15)
jumper
Table 6-7: E8 and E10A debugger links.
Table 6-8 below describes the function of the option links associated with power source. The default configuration is indicated by BOLD
text.
14