Polycom C8 Stereo System User Manual


 
Hardware Installation Guide for the Polycom SoundStructure C16, C12, C8 and SR12
1 - 6
General Site Requirements
Please ensure the SoundStructure side ventilation holes have at least 1 inch of
clearance from the sides of the rack to allow airflow through the device.
Failure to maintain clearance for airflow may increase the operating
temperature of the unit beyond its maximum operating temperature of 40° C
(104° F).
With the proper side clearance, each SoundStructure device requires one rack
space and does not require additional empty rack spaces above or below the
device. When mounting with other equipment give consideration to having
access to the audio connectors on the rear-panel.
When using SoundStructure with Polycom HDX video codecs, it is
recommended that the SoundStructure devices be installed above the video
codec.
If you are placing the device on a tabletop or other flat surface (rather than
rack- mounting it), it is recommended to mount the adhesive rubber feet on the
bottom of the device as shown in Rack-Mounting The Polycom
SoundStructure Device to prevent damaging the finish of the furniture
surface.
Power Supply Considerations
The Polycom SoundStructure C16, C12, C8 and SR12 have the following
power requirements on the line power supplied to the devices:
Input voltage of 90-250 VAC; 50-60 Hz
Line power requirements (including 0.6 PF):
130 VA (C16),
115 VA (C12),
105 VA (SR12),
95 VA (C8)