Once it is SET by one of these commands:
a. It will remain set until power is cycled on the unit.
b. Non-address DIP switch changes on a connected KEYPAD connected to this zone will be ignored.
If override state is "0", this response is also issued whenever non-address KEYPAD DIP switches are changed.
*********************************************************************************
COMMAND: *ZxxON<CR> – Turn zone xx ON.
RESPONSE: Same response as for *ZxxCONSR<CR>
*********************************************************************************
COMMAND: *ZxxOFF<CR> – Turn zone xx OFF.
RESPONSE: Same response as for *ZxxCONSR<CR>
*********************************************************************************
COMMAND: *ALLOFF<CR> – Turn ALL zones OFF.
RESPONSE: #ALLOFF<CR>
This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.
*********************************************************************************
COMMAND: *ALLV+<CR> – Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps.
RESPONSE: #ALLV+<CR>
The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an *ALLHLD<CR> Command is received. Note that to stop the
ramp with this command before maximum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR> Command to determine
when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same
rate.
*********************************************************************************
COMMAND: *ALLV-<CR> – Ramp ALL zones DOWN at a 10 dB/second rate in 1 dB steps.
RESPONSE: #ALLV-<CR>
The ramp action will be cancelled when all zones reach MINIMUM (OFF) volume, or when an *ALLHLD<CR> Command is received. Note that to
stop the ramp with this command before the minimum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR> Command
to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp
at the same rate.
*********************************************************************************
COMMAND: *ALLHLD<CR> – Stops ramp action initiated by *ALLV+<CR> Or *ALLV-<CR>
RESPONSE: #ALLHLD-<CR>
This results in a HOLD of the level at time of command receipt.
*********************************************************************************
COMMAND: *ALLMON<CR> – ALL MUTE ON.
RESPONSE: # ALLMON<CR>
*********************************************************************************
COMMAND: *ALLMOFF<CR> – ALL MUTE OFF.
RESPONSE: #ALLMOFF<CR>
********************************************************************************
COMMAND: *ZxxSRCp<CR> – Switch zone xx to SOURCE p ( 1 to 6).
RESPONSE: Same response as for *ZxxCONSR<CR>
*********************************************************************************
28