Kenwood TS-870S Satellite Radio User Manual


 
91
APPENDICES
1
Sets RX/TX (VFO A/B, memory channel).
FR
2
Parameter Format Parameter function
P1 3 FUNCTION
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
FP1;
FP1;
F R/T ;
4567891011121314
FT
FUNCTION RX, FUNCTION TX
R/T
R/T
1
Reads status of the transceiver.
IF INFORMATION
2
Parameter Format Parameter function
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
P15
4
5
1
1
7
11
2
3
1
1
1
14
FREQUENCY
NOT USED
RIT/XIT FREQUENCY
RIT OFF/ON
XIT OFF/ON
NOT USED
MEMORY CHANNEL
TX/RX
MODE
FUNCTION
SCAN OFF/ON
SPLIT OFF/ON
TONE OFF/ON
TONE NUMBER
NOT USED
34567891011121314
15
Input commands FunctionOutput commands
Set
command
Read
command
Answer command
16 17 18 19 20 21 22 23 24 25 26 27 28
123
IF;
4567891011121314
15 16 17 18 19 20 21 22 23 24 25 26 27 28
123456
IF P1
7891011 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27
P7P4P3
28
29 30 31 32 33 34
P8 P9 P10 P11 P12 P13
35
P14
36 37 38
;
39 40 41 42
P5
1
Fine function OFF/ON
FS
FINE STEP
2
Parameter Format Parameter function
P1 1 FINE OFF/ON
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
FSP1;
FSP1;
FS;
4567891011121314
1
Sets or reads IF shift. For SSB and AM, sets or reads the low-pass filter
cut-off frequency.
IS
IF SHIFT
Note:
If P2 is positive or zero, P1 can be “+” or “ ”.
Allowable data (in units of Hz):
SSB: 1400, 1600, 1800, 2000, 2200,
2400, 2600, 2800, 3000, 3400, 4600, 6000
AM: 2500, 3000, 4000, 5000, 6000,
7000,
CW: 400~1000 (50 Hz steps)
2
Parameter Format Parameter function
P1
P2
40
41
IF SHIFT
DIRECTION
IF SHIFT
FREQUENCY
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
ISP1 P2 ;
ISP1 P2 ;
IS;
4567891011121314
1
Sets or reads keying speed while using the KY command.
KS
KEYER SPEED
2
Parameter Format Parameter function
P1 42
KEYER SPEED
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
KS
P1
;
KS;
4567891011121314
P1KS
;
1
Sets or reads filter bandwidth. For SSB and AM, sets or reads the
high-pass filter cut-off frequency.
FW
FILTER WIDTH
2
Parameter Format Parameter function
P1 38
FILTER WIDTH
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
FW
P1
;
FW;
4567891011121314
P1
FW
;
Note:
Allowable data(units of 10 Hz):
SSB:
CW:
FSK:
FM:
AM:
0, 5, 10, 20, 30, 40, 50, 60, 80, 100
5, 10, 20, 40, 60, 100
25, 50, 100, 150
500, 600, 800, 1000, 1200, 1400
0, 10, 20, 50
1
Sets or reads AGC time constant.
GT
AUTO GAIN CONTROL TIME CONSTANT
2
Parameter Format Parameter function
P1 39
AGC TIME CONSTANT
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
GT
P1
;
GT;
4567891011121314
P1GT
;
1
Reads Model number of the transceiver.
ID
IDENTIFICATION
2
Parameter Format Parameter function
P1 16 MODEL NUMBER
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
ID P1
;
ID;
4567891011121314
1
Converts input characters into Morse code.
KY CW KEYING
2
Parameter Format Parameter function
P1
43
KEYER MESSAGE
KEYER BUFFER
34567891011121314
15
Input commands FunctionOutput commands
Set
command
Read
command
Answer command
16 17 18 19 20 21 22 23 24 25 26 27 28
1234567891011121314
15 16 17 18 19 20 21 22 23 24 25 26 27 28
123456
K
P1
7891011 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27 28
29 30 31 32 33 34
P2
35 36 37 38 39 40 41 42
;
;
;
K
KY
Y
Y
P2
44
Note:
The Set command requires a " " (ASCII
code 20h) in the third byte position.
Insert " " for bytes that have no
characters to make a 28-byte fixed length
command.
The " " bytes will not send any character.
Supported characters include: Letters,
numbers, " ' (( )) ( )
+
,. / : = ?
The internal buffer allows approximately
5 times 28 characters (~140 characters) to be
continuously keyed. For programs that
convert to Morse code immediately after entry,
more continuous keying is possible
Ex:
CQ CQ CQ DE WD6DJY WD6DJY WD6DJY K
KY_CQ_CQ_ CQ_DE_ WD6DJY_ WD6DJ;
KY_Y_ WD6DJY_K_______________ ;