Icom IC-M501EURO Stereo System User Manual


 
Setting tag channels
For more efficient scanning, add desired channels as tag
channels or clear tag channels for unwanted channels. Chan-
nels set as non-tag channels will be skipped during scanning.
Tag channels can be assigned to each channel group (Inter-
national, U.S.A., Holland, DSC, ATIS) independently.
q While pushing [HI/LO], push [DIAL] one or more times to
select the desired channel group, if desired.
w Select the desired channel to set as a tag channel.
e Push [SCAN/TAG] for 1 sec. to set the displayed channel
as a tag channel.
•“TAG appears in the function display.
r To cancel the tag channel setting, repeat e.
•“TAG disappears.
Clearing all tag channels in the selected channel group
While pushing [HI/LO], push [DIAL] for 3 sec. to clear all
tag channels in the channel group.
Starting a scan
Set scan type (priority or normal scan) and scan resume timer
in advance using set mode. (p. 15)
q Set tag channels as described at left.
w While pushing [HI/LO], push [DIAL] one or more times to
select the desired channel group, if desired.
e Push [SCAN] to start priority or normal scan.
•“Pri scan 16 or Normal scan appears in the function display.
When a signal is detected, scan pauses until the signal disap-
pears or resumes after pausing 5 sec. according to set mode set-
ting. (Channel 16 is still monitored during priority scan.)
Rotate the channel selector to check the scanning tag channels,
to change the scanning direction or resume the scan manually.
•“16 ashes and a beep tone sounds when a signal is received
on channel 16 during priority scan.
r To stop the scan, push [SCAN].
•“Pri scan or Normal scan disappears.
5
SCAN OPERATION
13
INT
25W
DUPTAG
INTL
INT
25W
DUPTAG
Normalscan
BUSY INT
25W
DUPTAG
Normalscan
SCAN
TAG
Push
Scan starts. When a signal is received
[Example]: Starting a normal scan.
0 IC-M501EURO_3.qxd 03.7.29 15:26 Page 13