Figures 4-1 thru 4-22 provide the guidelines for wiring
the sensor to various Analyzer/Transmitter instruments.
To determine which wiring guideline to use, locate the
model number of the sensor to be installed.
1. If the cable needs to be extended, use a high qual-
ity eleven conductor double shielded instrument
cable available from Rosemount Analytical. Refer
to Table 4-1 to refer to the appropriate junction box
to use and the corresponding wiring details.
NOTE
If the cable is too long, loop up the excess
cable. If the cable has to be shortened, cut and
terminate each conductor neatly and make
sure that the overall (outermost) drain wire
is not shorted out with either of the two
inner drain wires (shields).
2. Signal cable should be run in a dedicated conduit
(preferably an earth grounded metallic conduit)
and should be kept away from AC power lines. For
your convenience, a wire nut kit is furnished (in a
plastic bag wrapped around the cable).
NOTE
For maximum EMI/RFI protection when wiring
from the sensor to the junction box, the outer
braid of the sensor should be connected to the
outer braided shield of the extension cable.
The outer braid of the extension cable to the
instrument must be terminated at earth ground
or by using an appropriate metal cable gland
fitting that provides a secure connection to the
instrument cable.
TABLE 4-1. Wiring Matrix Guide
MODEL 396P and 396PVP SECTION 4.0
WIRING - MODEL 396PVP
SECTION 4.0
WIRING — MODELS 396P-02 AND 396PVP
Preamplifier Location Analyzer/Transmitter
Sensor Integral to Integral to Remote Interconnect 1054A, 54, 81, 1055 1181 1050 1003 SCL or Refer to
Model Sensor Analyzer Junction (unprepped 1054B, 2054 3081, 1060 1023 SoluCube Figure
Options
Box (PN) PN) 2081 4081, 5081 #
396P-02-()-55 ✓✓4-3, 4-6,
396PVP-55 4-9
396P-02-()-50 ✓✓4-4
396PVP-50
396P-02-()-50 23309-03 9200254 ✓✓✓ 4-22
396PVP-50
396P-02-()-50 23309-03 9200273 or ✓✓✓ 4-8
396PVP-50 23646-01
396P-02-()-54 23309-04 9200254 4-23
396P-02-()-54 23309-04 9200273 or 4-20
396PVP-54 23646-01
396P-02-()-54 ✓✓ 4-5, 4-18
396PVP-54 4-19
396P-02-()-55 23555-00 9200273 or 4-7, 4-10
396PVP-55 23646-01 4-12
396P-02-()-54
661-898695
4-14
396PVP-54
396P-02-54 23309-04 9200273 or
4-11
396PVP-54 23646-01
4-21
396P-02-55
✓✓4-15
396PVP-55 4-16
396P-02-55
9200273 or
4-17
396PVP-55 23646-01