Reference Manual MAS2600: Ordering Information
Ed 21 December 2014
10
MAS2600 Ordering Information
Type
A Absolute Transducer
G Gauge Transducer
H High Temperature Gauge Transducer
Transducer Ranges
1
3,5 mH
2
O gauge
2
7,0 mH
2
O gauge
3
16,0 mH
2
O gauge
4
35,0 mH
2
O gauge or 0,8 to 3,5 bar absolute
7 0,8 to 2,0 bar absolute
Temperature Sensor
0 without
1 Built-in Pt 100 (not available for IS installations)
Cable (length in meters)
XX
Standard cable (-20° to 80° C)
Maximum length: Hazardous area 44 m, Safe area 300 m
XX
High temperature cable (-20° to 125° C) (-20° to 80° C for IS installation)
Maximum length: Hazardous area 34 m, Safe area 300 m
Mounting
0 without fittings
1 brackets for internal mounting
2 pole mounting
3 1” pipe end mounting
4 flange mounting DN 25
5 flange mounting DN 40
6 flange mounting DN 50
9 flexible rubber tube mounting (add length in mm)
P flexible PTFE tube mounting (add length in mm)
V DN 25 flange with 1” ball valve mounting
A - M replacement
Amplifier Box
0 not supplied
1 standard box with PG 11 / PG 11
2 standard box with PG 11 / PG 13,5
3 standard box with PG 11 / PG 16
5 standard box with PG 13,5 / PG 13,5
Amplifier PCB
0 not supplied
P programmable output range gauge
D differential output range gauge
X X X - XX - X /