6. It is the responsibility of the user to ensure the voltage and current limits for this
equipment are not exceeded.
7. Technical Data:
a. Materials of construction:
UPVC moulded body and front face. PVC sheathed 2 core shielded cable.
Glass filled nylon lock nut. 316SS hanging bracket. Epoxy adhesive sealant.
b. Coding:
ATEX: II 1 G, Ex ia IIC Ga, T6 (Ta = –40 to 55 °C), T4 (Ta = –40 to 60 °C)
IECEx:Ex ia IIC Ga, T6 (Ta = –40 to 55 °C), T4 (Ta = –40 to 60 °C)
Ui = 30V, li = 120mA, Pi = 0.82W, Li = 27H, Ci = 5nF
8. Special conditions for safe use:
a. The equipment must not be installed directly in any process where the
enclosure might be charged by the rapid flow of non-conductive media.
b. The equipment must only be cleaned with a damp cloth.
c. Do not mount the 3107/3108 on a structure that is subject to vibration, or in a
position where damage may be caused by impact or thermal stress.
d. The equipment is not intended to be used in areas exposed to dust.
9. Manufacturer:
Rosemount Measurement Limited
158 Edinburgh Avenue, Slough, Berkshire, SL1 4UE, UK