EFJohnson 761X Speaker User Manual


 
PROGRAMMING
4-11
November 1998
Part No. 001-7600-001
Parameter Description
Stop Timer
When Mode 2 or 3 above is programmed (priority scanning), this sets how often in seconds the priority channel
is checked while receiving a message on some other channel.
Resume
Timer
This sets the scan resume delay in seconds. This is the time that elapses before scanning resumes after a
message is received.
PWR ON
Scan
If this function is programmed “On”, scanning starts automatically when transceiver power is turned on. The
“Hanger Action” parameter in Table 4-2 should also be programmed for “Scan” if power-on scan is used. If
scanning halts to transmit a message, the timer selected for Auto Reset parameter in the channel screen (see
Table 4-1) determines the delay before scanning resumes. See also Scan A/B function in Key Assign screen
(Table 4-2), “Scan” column in 2-Tone Code CH screen (Table 4-6), “Timer A/B” in Common screen
(Table 4-7), and “Fast/Slow Scan Timer” in Expert screen (Table 4-8).
Auto CH
Call
The parameter is displayed only in the PMR (European) mode, and is used with the 5-tone option. If “On” is
programmed, pressing the CALL key (1) starts scanning, (2) detects a non-busy channel, and (3) transmits the
5-tone codes.
Table 4-6 2-Tone Code Channel Screen Description
Parameter Description
Rx Freq
1st/2nd
Sets the frequencies for the first and second tones from 250-3300 Hz. The closest tone is selected.
Group Call
Programs if the 1st or 2nd tone is used for the group code.
Text
Programs the text that is displayed when a matched 2-tone is received. The characters and other information
described for “TEXT” in Table 4-1 also applies to this text.
Bell
Selects the bell indicator condition when receiving a matched 2-tone. The following conditions can be
programmed:
Null -
The bell indicator condition is not changed, even when a matched code is received.
Off -
The bell indicator goes off.
On -
The bell indicator appears until a key is pressed.
Blink -
The bell indicator blinks until a key is pressed.
ANS
Turns the Answer Back function on and off. This function transmits a 1 kHz single tone for 2 seconds when
receiving a matched 2-tone code.
EXO
“On” activates an external alert such as a horn or buzzer when a matching 2-tone code is received. The activa-
tion time is set by “EXO Timer” in the Rx Code Common screen (see below). The optional accessory cable is
required to utilize this feature.
Table 4-5 Scan Function Screen Description (Continued)
NOTE: Optional
2/5-Tone Module,
P.N. 585-7500-
026, is required to
utilize the two-
tone feature.