Dynacord Professional Power Amplifiers Stereo Amplifier User Manual


 
rCM-26
21
loudspeaker cabinets and systems, factory presets are
available with linear phase ‚brick-wall‘ FIR crossovers.
These provide users wishing to tune the system themselves
with a completely linearized frequency and phase response
upon which to build.
SYSTEM FREQUENCY RESPONSE IN DISPLAY
For DYNACORD loudspeaker cabinets, measurements
of the frequency and phase response are already
provided in the IRIS-Net. This data together with the
filter, crossover and delay settings conducted in the
RCM-26 can be displayed and taken into account by
IRIS-Net. The superposition shows the actual frequency
response of the loudspeaker cabinet.
REMOTE FUNCTIONS
Remote control of the power amplifier under IRIS-Net
provides Power On / Standby switching and the
programming of power-up sequences for the power
amplifiers as well as level settings and the muting of
individual channels or channel groups. In the RCM-26,
all parameters can be controlled in real time as well
as stored in user memories, from which they can be
retrieved and reloaded subsequently.
DSP FUNCTIONS
X-over:• Linkwitz-Riley, Butterworth, Bessel
FIR Filters:• zero latency
processing, linear phase X-over
Master EQ:• 6 filters per channel; PEQ,
lo-shelf, hi-shelf, hi-pass, lo-pass selectable
Channel EQ:• 6 filters per channel; PEQ, lo-shelf,
hi-shelf, hi-pass, lo-pass, all-pass selectable
Master delay :• 2ms - 2000ms per channel
Channel delay:• speaker alignment
Dynamics:• compressor, limiter per channel
Protection:• Advanced Digital
Voice Coil Protection algorithms
Others:• input routing, level, mute,
polarity, sine and noise generators, VU meter