2.6 Restore the Factory Default Settings
When troubleshooting configuration problems, it is sometimes convenient to restore the device to a
known state.
Each loudspeaker amplifier is delivered with factory se
t default values for the parameters indicated
in Table 2-14. Use the RT
FM switch on the loudspeaker amplifier face to restore these parameters to
the factory default settings.
When you use the RTFM switch, the factor
y default settings are restored for only the parameters
indicated in Table 2-14. The other parameters in the current loudspeaker amplifier
configuration
will remain unchanged.
To restore these parameters to the factory default settings:
1. Press and hold the RTFM
switch for 20 seconds.
2. The loudspeaker amplifier will beep after one sec
ond. Continue to hold the switch until the
loudspeaker amplifier beeps again after 20 seconds.
3. Release the switch. The following occurs:
• A voice message announces that the factory default
settings are being restored.
• Once the settings are restored, a voice message
announces the restored default IP address:
192.168.3.10
• A voice message announces that the loudspeaker amplifier is rebooting.
• The loudspeaker amplifier reboots.
Table 2-14. Factory Default Settings
Parameter Factory Default Setting
IP Addressing static
IP Address 192.168.3.10
Web Access Username admin
Web Access Password admin
Subnet Mask 255.255.255.0
Default Gateway 192.168.3.1