Cooper Lighting Radio Stereo System User Manual


 
Page 8 of 21 WR 3M
2. Depress the UP or DOWN Scroll Key. The display switches to the
set value. The temperature symbol (18) flashes.
3. Depress the UP or DOWN Scroll Key to set the desired
temperature:
- Tapping the Scroll Keys changes the Set temperature by one
degree.
- Holding down the Scroll Keys changes the Set temperature
rapidly.
The Set value of the selected channel appears in the display for
approximately 2 seconds after the Scroll Keys are released.
Setting the Pre-set Temperature on Radio Buttons ┌ 1 ┐,┌ 2 ┐ or ┌ 3
The temperature can be set for each channel separately by selecting
three fixed/pre-set Radio Buttons.
1. Select a channel.
Three fixed/pre-set temperatures are shown in the display for
approximately 2 seconds. The temperature can now be Set as
long as the temperature symbol is flashing.
2. Adjust the temperature in the large display with the UP or DOWN
Scroll Keys.
3. Depress the desired Radio Button ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐ for 3
seconds. The temperature display for the corresponding
temperature value flashes during this period. The Set value is
stored after 3 seconds.
4. Release the Radio Button.
Temperature Setting using the Radio Buttons ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐
Factory default settings:
┌ 1 ┐ = 300 °F ( 150 °C ),
┌ 2 ┐ = 660 °F ( 350 °C ),
┌ 3 ┐ = 720 °F ( 380 °C )
1. Select a channel.
Three fixed/pre-set temperatures are shown in the display for
approximately 2 seconds. The temperature can now be Set as
long as the temperature symbol is flashing.
2. The desired fixed/pre-set temperature can now be selected with
Radio Buttons ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐
3. The Set value is adopted. The Read temperature of the selected
channel is displayed after 3 seconds.
6.3 Setting the Air Flow
The Air Flow can, starting from a maximum flow value of 15 l/s (HAP
200) or 10 l/s (HAP 1), be adjusted between 10% to 100%.
1. Depress the AIR button.