7
INPUT WIRING
Balanced Inputs
Balanced input wiring requires two conductors with shield (22-gauge is the most common). The use of
crimp type spade lugs is highly recommended for permanent installations. At the input section located on
the rear of the amplier, wire the “hot”/positive lead to the “+” terminal, the “common”/negative lead to the
“-” terminal and the shield/drain to the “ground” terminal (Figure 3).
The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female patch
cables to accommodate outputs from a mixer, equalizer, or crossover when the amplier is used as a
portable sound system amplier.
Figure 3
Black (-)
Shield
White (+)
Black (-)
Shield
White (+)