Asus DSBV-DX/SAS Home Theater System User Manual


 
ASUS DSBV-DX Series 5-41
6. The Create New Array screen shows the disks you can add to make up
the IM volume. Use the arrow key to select a disk, then move the cursor to
the RAID Disk column. To include this disk in the array, press <+>, <->, or
<Space>.
You may also specify the Hot Spare disk here. Select the disk, then move the
cursor to the Hot Spr column, then press <+>, <->, or <Space>.
By default, the RAID Disk eld shows No before array creation. This eld is
grayed out under the following conditions:
The disk does not meet the minimum requirements for use in a RAID array.
The disk is not large enough to mirror existing data on the primary drive.
The disk has been selected as the Hot Spare for the RAID array.
The disk is already part of another array.
Esc = Exit Menu F1/Shift+1 = Help
SPACE/+/- = Select disk for array or hot spare C = Create array
LSILogicCongUtilityv6.08.05.00(2006.08.02)
Create New Array -- SAS1068
Array Type: IM
Array Size(MB): ------
SlotDeviceIdentierRAIDHotDrivePredSize
Num Disk Spr Status Fail (MB)
0
SEAGATE ST373454SS 0003 [NO] [NO] ------- ---- 70007
1 SEAGATE ST373454SS 0003
[NO] [NO] ------- ---- 70007
2 SEAGATE ST373454SS 0003
[NO] [NO] ------- ---- 35003
3 SEAGATE ST373454SS 0003
[NO] [NO] ------- ---- 35003