A SERVICE OF

logo

3. Press [DISARM] to stop the siren.
The lights remain on.
4. Press [LIGHT OFF] on the Remote
Control to turn off
lights
connected
to modules which you set to the
same Housecode and Unit Code as
the Console.
Delay Mode
(HT544 and SH624 only)
1. Set the Delay switch on the
HT544
or
SH624
Remote Control to MAX.
2. Press [ARM] on the Remote Con-
trol. Lamps connected to modules
set to the same Housecode and Unit
Code as the Console turn on. The
Console chimes for approximately
1 minute while you leave the
house. You then hear a beep signi-
fying that the system is armed, and
the lamp(s) turn off.
Open a door (that has its sensor set
to MAX).
The
Console gives a
pre-
alarm
beep,
and lamps connected to
modules set to the same Housecode
and Unit Code as the Console turn
on. After a delay of approximately
30 seconds the
alarm
sounds, lamps
connected to Lamp and Wall
Switch Modules (set to same
Housecode as the Console)
flash,
and the automatic
dialer
dials
out.
3. Press
[DISARM]
to stop the siren.
The lights remain on.
Note: Delayed arm/alarm only
affects
sensors set to MAX. If you open a
window (with its sensor set to
MIN)
the alarm trips instantly even if the
system is armed for delayed alarm.
ARM HOME/ARM AWAY
(SH624 only)
The SH624 Remote Control lets you
arm the system with or without Mo-
tion Detectors armed
If you press [ARM AWAY] on the
SH624 Remote Control, all Door/
Window Sensors AND Motion Detec-
tors will be armed.
If you press [ARM HOME] on the
SH624 Remote Control, ONLY Door/
Window Sensors
will
be armed. The
SP554A
Motion Detectors
will
not be
armed. This lets you arm the system at
night without accidentally tripping the
system yourself when you move
around the house.
Note: this feature requires the
SP554A
Motion Detector. It
wilI
not work with
the older
SP554.
If you use the older
SP554,
the [ARM HOME] button
wilI
work like the [ARM AWAY] button.
I.E. both the [ARM HOME] and
[ARM AWAY] buttons will arm
Door/Window Sensors AND
SP554
Motion Detectors.
If using the older
SP554
you can
choose to set it to MIN or MAX (with
or without entry/exit delay). If using
the newer
SP554A
it will always be in
the MIN (instant alarm) mode.
The
MIN/MAX
switch on the SH624
lets you set it to arm the system with
or without an exit/entry delay. When
set to MIN everything in the system
will
arm and trip instantly. When set
to MAX,
SP544s
(not
SP554As)
and
DW534s
set to MAX will have a 1
minute exit and a 30 sec. entry delay.
17
Smarthome.com, Inc. (800) SMART-HOME (949) 221-9200 http://smarthome.com