A SERVICE OF

logo

56 Service Manual
4039-1XX
Fuser Solenoid
Note:
The fuser solenoid must be mounted on the fuser for this
adjustment and should be at room temperature.
1. Loosen screw [
A
].
2. Remove the rubber washer.
3. Rotate shaft [
B
] (eccentric) to obtain 4.2 mm ± 0.2 mm
(0.165 in.± 0.008 in.) air gap.
4. Tighten screw [
A
].
5. Replace the rubber washer.