Product Description Model Number Quantity
Generator front-ends Generator front-ends 660MHz, RZ/NRZ, 3.5 Vpp, variable transition times SMA (f). Agilent E4838A
Generator front-end 330 MHz, RZ/NRZ, variable transition times SMA (f). Agilent E4842A
Generator front-end 660 MHz, RZ/NRZ, single channel, 2.5 Vpp SMA (f). Agilent E4843A
Dual generator front-end 200 Mbit/s, NRZ, 3.5 VPP SMA (f). Agilent E4846A
Analyzer front-ends Differential analyzer front-end 660 Msa/s, 1 GHz bandwidth, 50SMA (f). Agilent E4837A
Single analyzer front-end 660 Msa/s, 1 GHz bandwidth, 50SMA (f). Agilent E4844A
Dual analyzer front-end 330 Msa/s, 1 GHz bandwidth, 50SMA (f). Agilent E4845A
High impedance dual analyzer front-end 330 Msa/s, 350 MHz bandwidth, 50SMA (f). Agilent E4847A
Modules 660 MHz data generator/analyzer module – holds four front-ends, any mix Agilent E4841A
660 MHz clock and data generator module – holds two generator front-ends, any mix.
Clocks up to six Agilent E4841A modules. Agilent E4831A
660 MHz central clock module, which clocks up to eleven Agilent E4841A modules Agilent E4805A
and up to two Agilent E4805s.
Required in all systems that include analyzer front-ends, and for all systems with seven Agilent E4805A
or more Agilent E4841As.
8-line trigger input for TTL signals. When branching on external events Agilent E4805A
(hardware signals) other than VXI-ECL trigger lines or compare errors is required. Opt 002
Deskewprobe, includes Agilent 1144A 880 MHz active probe and a BNC (f) to SMA (m) Agilent E4805A
adapter (part number 1250-1200). Opt 003
Which clock module?
The Agilent E4831A Clock & Data
Generator Module can be an eco-
nomic way of building pulse or
data generators as it includes slots
for two front-ends. Please remem-
ber that the Agilent E4831A can
only be used for generator chan-
nels. For applications needing
many channels, analyzer channels
or more than two looping levels,
use the Agilent E4805A Central
Clock Module.
STEP 3: Decision - VXI integration
or not
If you want to combine the Agilent
81200 modules with other VXI
modules to achieve an "open VXI
system," then go to STEP 4b.
If you want to use the Agilent
81200 as a “proprietary system,”
meaning the Agilent 81200 will not be
combined with other VXI modules in
one system, then go to STEP 4a.
STEP 4a: Selecting the mainframe
If you’ve made the decision to config-
ure a "proprietary system," you are
now in the position to select a main-
frame. Two mainframes are available,
the Agilent E4840A small frame with
three free slots and the Agilent
E4849B mainframe with 10 free
slots. Both mainframes include a
built-in PC running Windows NT
4.0®. The user software is also
installed. All modules and front-ends
ordered with the mainframes come
factory installed.
Front - ends Clock module Data generator/
analyzer modules
Generator-only systems.
(Two looping levels)
Agilent E4838A 660 MHz/MRZ
Agilent E4842A 330 MHz RZ/NRZ
(variable transitions)
Agilent E4843A 660 MHz RZ/NRZ
Agilent E4846A Dual 200 Mb/s, NRZ
Generator systems or generator/analyzer systems.
(Five looping levels)
Analyzer front ends
Agilent E4837A 660 MSa/s, differential
Agilent E4844A 660 MSa/s
Agilent E4845A Dual 330 MSa/s
Agilent E4847A High-impedance
dual 330 MSa/s
Agilent
E4831A
Clock & data
generator module
Agilent E4805A
Central clock module
Up to six Agilent E4841A
modules can be added when
more generator front-ends are needed.
Agilent E4841A
Data generator/
analyzer module(s)
+
+
+
Figure 2: Front-ends and modules
Figure 3: Mainframes and expanders
3 free slots
3-slot PC
10 free slots
3-slot PC
9 free slots
VXI bus
extender
VXI bus
extender
12 free slots
VXI bus
extender
12 free slots
Up to 8 front-ends
Agilent E480A
Embedded PC
Up to 36 front-ends
Agilent E4849B
+
(+)