A SERVICE OF

logo

Control Port Operation HDSL2 for General Distribution Installation and Maintenance Practice
28 61223HDSL2L2-5B
Figure 25. Total Access 3000 H2TU-C Loopback and Test Commands Screen
BERT Test Functions
The Bit Error Rate Testing (BERT) Test Screen (Figure 26) is accessed by selecting the
associated number on the
Loopback and Test menu. A five-selection menu is at the bottom of the
screen. Option 1,
(Re)start Pattern is used to start (or restart) a test, and option 2, Stop Test is
used to manually stop the test.
NOTE
The BERT only runs unframed patterns. When the BERT is
running, option 5 changes to Inject Bit Errors.
Shelf: 5 Slot: 22 Total Access System 03/01/05 09:29
Unacknowledged Alarms: None
Circuit ID:
Loopback and Test Commands
______ ______
|H2TU-C | |H2TU-R |
------>| | | |------>
| | | |
NET | |<--------->| | CUST
| | | |
<------| | | |<------
DSX-1 |______| |______| DS1
1. Run Self Tests
2. H2TU-C Loopup Network
3. H2TU-C Loopup Customer
4. H2TU-R Loopup Network
5. H2TU-R Loopup Customer
6. Equipment Jack = Unavailable
7. BERT Test Functions