A SERVICE OF

logo

HDSL2 for General Distribution Installation and Maintenance Practice Control Port Operation
61223HDSL2L2-5B 23
To re-deploy this unit, press D which restores the factory default settings to those shown in
Table 6 and Table 7. The options shown in these tables are available with the H2TU-R (P/N
1223026L2). Some settings may differ when using different H2TU-Rs.
Figure 17. Provisioning Menu, Page 1
Figure 18. Provisioning Menu, Page 2
Shelf: 1 Slot: 14 Total Access System 03/01/05 09:29
Unacknowledged Alarms: None
Circuit ID:
Provisioning
1. DSX-1 Line Buildout = 0-133 Feet
2. DSX-1/DS1 Line Code = B8ZS
3. DSX-1/DS1 Framing = ESF
4. Forced Frame Conversion = Disabled
5. Smartjack Loopback = Enabled
6. Loopback Timeout = 120 Min
7. Latching Loopback Mode = T1 (Disabled)
8. DS1 TX Level = 0 dB
9. Span Power = Enabled
10. Customer Loss Indicator = AIS / CI
11. PRM Setting = AUTO
12. Loop Atten Alarm Thres = 30dB
13. SNR Margin Alarm Thres = 04dB
14. Remote Provisioning = Enabled
15. Service State = OOS Maintenance
16. Network Source = DSX
N. Next Page
Selection:
Shelf: 1 Slot: 14 Total Access System 03/01/05 09:29
Unacknowledged Alarms: None
Circuit ID:HntsvlALMn0103
Provisioning
17. External Alarms = Disabled
18. Auto In Service = Enabled
19. Auto IS Startup Period = 4 hours
20. Auto IS Off Period = 8 hours
D. Restore Factory Defaults
P. Previous Page
Selection: