![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/ad/4ad4c32f-ee96-48c7-ad81-bd1c6cf55acd/4ad4c32f-ee96-48c7-ad81-bd1c6cf55acd-bg32.png)
Regarding the indicator lamps
Lighting and fl ashing of the POWER indicator, the LAMP indicator, and the TEMP
indicator have the meanings as described in the table below. Please respond
in accordance with the instructions within the table. If the same indication is
displayed after the treatment, or if an indication other than the following is
displayed, please contact your dealer or service company.
The projector is in a standby state.
Please refer to the section “Power On/Off”.
The projector is warming up.
The projector is in an on state.
Ordinary operations may be performed.
The projector is cooling down.
The projector is cooling down. A certain error
Please wait until the POWER indicator fi nishes blink,
and then perform the proper response measure using
the item descriptions below as reference.
The lamp does not light, and there is a
possibility that interior portion has become
Please turn the power off, and allow the unit to cool
down at least 20 minutes. After the projector has
suffi ciently cooled down, please make confi rmation of
the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treatment,
please change the lamp by referring to the section
The lamp door has not been properly fi xed
Please turn the power off, and allow the unit to cool
down at least 45 minutes.
suffi ciently cooled down, please make confi rmation of
any needed maintenance, turn the power on again.
the same indication is displayed after the treatment,
please contact your dealer or service company.