Dual T1/PRI Status Displays
4-5
The ID (slot #) column represents the chassis slot numbers, 1–16
The status column displays one of these:
■
AVAIL
The NETServer PRI is installed in the corresponding chassis slot and
is idle.
■
Un-Avail
There is no NETServer PRI installed in the corresponding slot, or it is
not responding.
■
In-Use
The NETServer PRI is installed in the corresponding chassis slot and
is active.
The number of calls column indicates how many calls the NETServer PRI is
handling.
Menu Options
6 and 8
Checking span line 1 and 2’s DS0 status
Status menu options 6 and 8 allow you to monitor the individual DS0
status of span lines 1 and 2, respectively.
The status column displays one of these:
■
Connected-In
The time slot is active with a call originated from a remote device
through the TELCO.
■
Connected-Out
The time slot is active with a call originated by the chassis.
■
Dialing-In
An incoming call is received and is being processed.
■
Dialing-Out
An outgoing call is being processed.
■
Disconn
The time slot’s call is disconnecting.