![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/25/c25fd9b9-ce4c-4f2c-a260-c0afdac8fd7e/c25fd9b9-ce4c-4f2c-a260-c0afdac8fd7e-bg25.png)
Dual T1/PRI Status Displays
4-3
■
Line Interface Unit 1/2
The power-up code verifies whether or not the NIC is present and
then configures the CSU on the NIC to local loopback mode.
The failure level for this test is Non-critical.
■
Flash ROM 12v Test
This self-test checks and verifies that the 12v circuitry to the Flash
ROM functions properly. The failure level for this test is Non-critical.
■
HDLC Channel 1/2
The code checks the HDLC controller channels 1 and 2. The HDL
controller is used for D-channel signaling. The failure level for this
test is Non-Critical.
Menu Option 2 Checking the T1/PRI’s overall status
This status screen provides status information for:
■
Current PRI timing source
■
Current packet bus timing source
■
What type of NIC is installed behind the NAC
■
What chassis slot the NAC is installed in
■
How much time elapsed since the NAC was last reset
■
How much DRAM is installed on the NAC
■
How much Flash ROM is installed on the NAC
Menu Option 3 Checking chassis slot device configurations
Status menu option 3 allows you to verify if you configured the chassis
slot assignments correctly in option 5 of the card configuration menu.
The slot # column represents the chassis slot numbers, 1–16.
The device type column indicates the type of NAC installed and assigned
in the corresponding chassis slot. It displays one of these:
■
NONE
No NAC is installed and assigned to that particular slot.