PC3301N
PC2001N
1/8 power is typical of program material with occasional clipping. Refer to these figures for most applications.
1/3 power represents program material with extremely heavy clipping.
Test signal: Pink Noise, bandwidth limited from 22Hz to 22kHz
1W = 0.860kcal/h, 1BTU = 0.252kcal
Note that Line Voltage [V] x Line Current [A] = [VA], not equals to [W].
Inrush current
PC9501N: 7A (100V), 8A (120V), 16A (240V)
PC6501N, PC4801N, PC3301N, PC2001N: 10A (100V), 12A (120V), 23A (240V)
Line Current (A) Power (W) Thermal Dissipation
100/120V 230/240V In Out Dissipated Btu/h kcal/h
standby 0.08 0.04505174
idle 1.0 0.5 40 0 40 137 34
1/8 power
8 Ω/ch 2.7 1.5 189 88 102 348 88
4 Ω/ch 5.0 2.7 357 150 207 707 178
1/3 power
8 Ω/ch 6.4 3.5 459 233 226 771 194
4 Ω/ch 12.0 6.6 866 400 466 1590 401
Line Current (A) Power (W) Thermal Dissipation
100/120V 230/240V In Out Dissipated Btu/h kcal/h
standby 0.08 0.04505174
idle 1.0 0.5 40 0 40 137 34
1/8 power
8 Ω/ch 1.9 1.1 134 58 77 261 66
4 Ω/ch 3.1 1.7 224 88 137 467 118
1/3 power
8 Ω/ch 4.5 2.5 325 153 172 586 148
4 Ω/ch 7.6 4.2 544 233 311 1060 267
IMPORTANT NOTICE FOR THE UNITED KINGDOM
Connecting the Plug and Cord
WARNING: THIS APPARATUS MUST BE EARTHED
IMPORTANT. The wires in this mains lead are coloured in accordance
with the following code:
GREEN-AND-YELLOW : EARTH
BLUE : NEUTRAL
BROWN : LIVE
As the colours of the wires in the mains lead of this apparatus may not
correspond with the coloured markings identifying the terminals in
your plug proceed as follows:
The wire which is coloured GREEN-and-YELLOW must be connected
to the terminal in the plug which is marked by the letter E or by the
safety earth symbol or colored GREEN or GREEN-and-YELLOW.
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the termi-
nal which is marked with the letter L or coloured RED.
• This applies only to products distributed by Yamaha-Kemble Music (U.K.) Ltd. (3 wires)
This mark indicates a dangerous electrically live terminal.
When connecting an external wire to this terminal, it is necessary
either to have “a person who have received appropriate
guidance on handling” make the connection or to use leads or a
cord that have been manufactured in such a way that the
connection can be made simply and without problem.