Uniden PC78 CD Player User Manual


 
RF Meter: Measures RF Output Power for transmitter. To use, position
the meter switch at S/RF. Press microphone PTT switch to read
transmitting power.
S-Meter: Measures incoming signal strength. To use, position the meter
switch at S/RF. The meter swings to indicate signal strength.
i.e. S 3, S 5, S 7 . . .
9
Preventive Maintenance
Maintenance
Use only the fuse specified for your PC78 Elite.
Failure to do so may void your warranty.
Every six months:
1. Check the Standing Wave Ratio (SWR).
2. Be sure all electrical connections are tight.
3. Inspect antenna coaxial cable for wear or breaks in shielding.
4. Be sure all screws and mounting hard ware are tight.
The PC78 Elite is designed to give you years of trouble-free service. There
are no user-serviceable parts inside. Except for the fuse in the DC power
cord, no maintenance is required.
To replace a blown fuse:
1. Press ends of the fuse holder
together. Twist to open.
Carefully separate the two pieces.
2. Remove the fuse and inspect.
If blown, replace with the same
type fuse.
UC343FH 10/23/03 2:32 PM Page 9