89
9000 series modules
Model No. Module function
No. of inputs Maximum mountable No.
D-001T 2-channel Mic/Line input 2 4
D-001R 2-channel Mic/Line input 2 4
ZP-001T Zone paging input 1 1
T-001T 2-channel output
–
3
C-001T Remote control
–
1
AN-001T 2-channel ambient noise sensor input 2 2
900 series modules 1 8
15.1. Module Combination
The unit is designed to provide an up to 8-input/8-output configuration in combination with its optional
modules.
Inputs are configured by only using the modules. (No input terminals are located on the rear panel.)
For outputs, 2 output channels are provided on the rear panel and can be expanded by adding modules.
There are 4 control inputs and 4 control outputs on the rear panel, which can be expanded to a maximum of
12 inputs and 12 outputs with the additional use of 1 module.
900 Series input modules can also be used together with 9000 Series modules.
15.2. Channel Numbers and Terminal Numbers
• Input channel numbers 1, 2, 3... begin with the input(s) of the module inserted into Slot No. 1.
• Output channels 1 and 2 correspond to the unit's rear panel-mounted preamplifier output terminals 1 and 2,
respectively. When output modules are added, the output channel numbers are 3, 4, 5....beginning with the
output of the module inserted into Slot 5.
• Control input and output terminal numbers correspond to control input and output terminals 1 – 4 on the unit's
rear panel. When a C-001T module is added, the additional terminal numbers are from 5 to 12.
15.3. Module Installation
The unit's rear panel-mounted module slot numbers are 1 – 8 from right to left as viewed from the rear.
There are rules for module installation. Follow the procedures below to mount the modules.
Notes
• Avoid touching parts and terminals on the module's circuit board when inserting or removing the module.
• Mount the module in the right place and certainly secure it with screws.
Step 1. Insert the D-001T or D-001R module into
the slots, starting in order from Slot 1
without leaving slots open in between.
Note
Only Slots 1 – 4 can be used for the D-001T
and D-001R modules. The main unit
recognizes the D-001R as the D-001T.
Slot 12345678
D-001T/R
15. MODULE INSTALLATION
Important Be sure to detach the power cord when inserting or removing any module.