(B5) Trigger setting (when Event classification is set to ROUTE)
EVENT01TR I
G
C- IN01
Set how to activate the selected Event.
• NONE: External control cannot be used for activation. Set the trigger setting here to NONE when
designating the selected Event number as a BGM pattern.
• VOX: The event is activated when the selected input channel receives a signal.
Note
The D-001T/R module must be used for input, and the VOX set to ON in the audio input setting.
• C-IN1 to C-IN04 (C-IN1 to C-IN12 when the C-001T module is used):
Closing the designated control input terminal activates the Event.
Assigning a function to this terminal overwrites the previously set function on it if there is.
The type of trigger is fixed to "LEVEL."
• ZM-IN01 to ZM-IN12:
The indications ZM-IN01 – 06 or 01 – 04 correspond to the control buttons of the ZM-9001 or ZM-
9002 connected to the 9000 Series amplifier's remote volume control terminal 1 (REMT VOL 1).
The indications of ZM-IN with subsequent numbers correspond to ZM-9001's or ZM-9002's control
buttons connected to the remote volume control terminal 2 (REMT VOL 2).
Pressing the designated control button activates the Event.
Assigning a function to the button overwrites the previously set function on it if there is.
The type of trigger is fixed to "PULSE."
NONE (default), VOX, C-IN01 – 04 (C-IN01 – 12 when C-001T is used)
ZM-IN01 – 12*
* Selectable only when the Remote controller type (p. 62-C26) is set to ZM-9001 or
ZM-9002, and the Trigger type (next item) to PULSE.
Setting Range
TR I
GG
ER=LEVEL
(B6) Trigger type setting (when Event classification is set to ROUTE, and Trigger to C-IN or ZM-IN)
Set the type of trigger to either LEVEL or PULSE.
This setting is valid for the input channels with Priority levels 1 to 7.
Refer to p. 94 "Operation by control input" for each trigger operation.
LEVEL (default), PULSE
Note: "LEVEL" is fixed when selecting "C-IN01" through "C-IN12" in the Trigger setting
(previous item), and "PULSE" is fixed when selecting "ZM-IN01" through "ZM-IN12."
Setting Range
• Select the output channel using the Output channel selection key. The name of selected output channel is
displayed on the screen. Then confirm the selection by setting the Output channel ON/OFF key to ON (the
output channel indicator, red dot on the VFD screen lights).
• Repeat above operations to set multiple outputs.
OUT1 – 2, Max. 8 when T-001Ts are used (default: OUT1)
Note: 2 or more channels selectable.
Setting Range
EVENT01
O
UT1
(B4) Output channel setting (when Event classification is set to ROUTE)
Output channel name
Note
When the trigger type is "PULSE" (the trigger is set for "ZM-IN"), be sure to make the Busy input terminal
setting (B7).