Perreaux 6160/P Stereo Amplifier User Manual


 
22
Clipping
Indicators
Each of the six channels of the 6160 have an independent LED indicator whic
h
will illuminate if the output approaches clipping, potentially causing damagin
g
distortion and is a warning to reduce volume to the indicated channel(s).
Caution!
When the clip indicator illuminates, that channel is approaching clipping.
This should be avoided, as clipping is the main reason for damage to
both amplifiers and loudspeakers.
Bridgeable
Outputs
The 6160 has the facility to combine two independent channels into a singl
e
higher output channel. The bridging switch allows the selection of two
independent channels, or the combining of two channels to form a single highe
r
output channel. Bridged channels offer considerably more power than two
channels individually.
Protection
Systems
AC Sense
The 6160 monitors the AC voltage at the secondary windings of the toroida
l
transformer, that in turn supply the rectification stages. In the event that th
e
toroidal transformer AC output should fail, the protection circuitry wil
l
disconnect the output. The output will be reconnected once the AC voltage has
been restored.
DC Rail Fuse
Each of the +VE and –VE DC rails supplying the output stages of each channe
l
are protected with a fuse. In the event that any one of the fuses should fail, th
e
protection circuitry will automatically detect the fault and disconnect the outpu
t
of the respective channel(s).
Earthing
Perreaux engineers pay particular attention to designing the product to ensur
e
maximum separation between internal signal and power earths, only meeting at
a
central starred point.
Earth
Isolation
Switch
The toggle switch on the rear of the 6160 allows the internal circuitry to b
e
isolated from the mains earth, whilst still maintaining an earth connection to th
e
chassis. This ensures the potentially fatal practice of using an AC cord-set wit
h
no earth connection, to alleviate system hum, is not required.
Highest
Quality PCBs
and
Components
Quality fiberglass PCBs, featuring heavy copper tracks and high-grad
e
components, are used throughout the 6160. This provides added stability unde
r
variable thermal or electrical loads and assures maximum signal integrity,
separation and product life.
Soft-Start
Circuitry
The 6160 utilises soft-start circuitry to protect the fuses and/or circuit breakers i
n
your home’s mains power supply. Without this circuit, the huge inrush curren
t
required to charge the 60,000µF of power supply capacitance can blow the fuses
or trip the circuit breakers.
Highly
Powered
Capable of continuously delivering 160W
RMS
into 8 (225W
RMS
into 4), th
e
6160 is highly powered. Utilising six high current Hitachi MOSFETs pe
r
channel, the 6160 handles even the most difficult loads with ease.