14.4 : SECUR ET - VEB EYEBOLT
The Tannoy VNET“ loudspeaker can be flown with high quality
VEB M10 eyebolts with collar to BS4278:1984. The loudspeakers
are equipped with internal steel braces, which also double as the
flying points, and accept VEB M10 eyebolts.
To install the VEB M10 eyebolts remove the original M10 counter
sunk screws from the locations you wish to install the VEB M10
eyebolts. Then replace these counter sunk M10 screws with the VEB
M10 eyebolts. The M10 insert on the rear of the cabinet also accepts
a VEB M10 eyebolt and should only be used for tilting the loudspeaker
to the desired angle.
Important: It is imperative for safety reasons that two
eyebolts linked to two independently fixed straps are
used per cabinet. VEB eyebolts should be installed
into the relative sides of the cabinet, and should NEVER
be installed on the top of the cabinet. Never suspend
one enclosure from another to form a line array or cluster using
these fittings.
The correct method is shown in figure 2.
Never attempt to use formed eyebolts i.e. formed from a steel
rod and bent into an eye.
Only use the outer fixing points on the top and sides of the VNET“
cabinet for fixing eyebolts. The inner two fixing points on each side
of the cabinet are for dedicated bracketry (VMY) only.
.