13.3 Biamp System Parameters
Parameter Unit/Name Low Section High Section
Gain (dB) 0 -1.0
Delay (ms) 0.167 0
Polarity Positive Positive
HPF Ä Freq (Hz) 42.5 1680
Slope (dB/oct) 24 24
Filter Shape Butterworth Linkwitz Riley
LPF Freq (Hz) 1470 Thru
Slope (dB/oct) 24 NA
Filter Shape Linkwitz Riley NA
Freq (Hz) 62.5 2720
Level (dB) +7 -4
Type Parametric Parametric
PEQ 1
Ä
Q / Bandwidth 2.0 / 0.5000 2.1 / 0.4719
Freq (Hz) 454 10700
Level (dB) -3 +5
Type Parametric Parametric
PEQ 2
Q / Bandwidth 1.7 / 0.5946 1.9 / 0.5297
Freq (Hz) 642 15100
Level (dB) -2 +3
Type Parametric 2.4 / 0.4204
PEQ 3
Q / Bandwidth 4.0 / 0.2500 NA
Freq (Hz) 1010 NA
Level (dB) +6 NA
Type Parametric NA
PEQ 4
Q / Bandwidth 4.0 / 0.2500 NA
Freq (Hz) NA NA
Level (dB) NA NA
Type NA NA
PEQ 5
Q / Bandwidth NA NA
Ä
Note : When using the V12HP with subs, set HPF on LF section @ 80 – 110Hz
(24dB/oct LR) and omit PEQ1 (on LF only)