Frequency response
Inputs (Analog)
4) INPUT SHORT.
5) Weighted network, input level.
Inputs (Digital)
Outputs
EQ
FM tuner section
Tuning range 87.5 - 108.0 MHz
Antenna FM wire antenna
Antenna terminals 75 ohms, unbalanced
Intermediate frequency 10.7 MHz
Sensitivity
Mono: 18.3 dBf, 2.2 µV/75 ohms
Stereo: 38.3 dBf, 22.5 µV/75 ohms
Useable sensitivity 11.2 dBf, 1 µV/75 ohms
S/N
Mono: 76 dB
Stereo: 70 dB
Harmonic distortion at 1 kHz
Mono: 0.3%
Stereo: 0.5%
Separation 45 dB at 1 kHz
Frequency response 30 Hz – 15 kHz,
+0.5/–2 dB
Selectivity 60 dB at 400 kHz
AM tuner section
Tuning range
Models of area code CEL, CEK, SP, AU, TW, KR
With 9-kHz tuning scale 531 – 1,602 kHz
Antenna Loop antenna
Intermediate frequency 450 kHz
Usable sensitivity 50 dB/m (at 1,000 kHz or
999 kHz)
S/N 54 dB (at 50 mV/m)
Harmonic distortion 0.5% (50 mV/m, 400 Hz)
Selectivity
At 9 kHz: 35 dB
Video section
Inputs/Outputs
Video: 1 Vp-p, 75 ohms
S-video: Y: 1 Vp-p, 75 ohms
C: 0.286 Vp-p, 75 ohms
COMPONENT VIDEO: Y: 1 Vp-p, 75 ohms
B-Y: 0.7 Vp-p, 75 ohms
R-Y: 0.7 Vp-p, 75 ohms
80 MHz HD Pass Through
General
Power requirements
PHONO RIAA equalization curve
±0.5 dB
MULTI CH IN, SA-CD/
CD, MD/TAPE, DVD,
TV/SAT, VIDEO 1, 2, 3
10 Hz – 100 kHz
+0.5/–2 dB (when
ANALOG DIRECT is
selected)
PHONO Sensitivity: 2.5 mV
Impedance: 50 kilohms
S/N
3)
: 86 dB
(A, 2.5 mV
4)
)
MULTI CH IN, SA-CD/
CD, MD/TAPE, DVD,
TV/SAT, VIDEO 1, 2, 3
Sensitivity: 150 mV
Impedance: 50 kilohms
S/N
4)
: 96 dB
(A, 150 mV
5)
)
DVD (Coaxial) Impedance: 75 ohms
S/N: 100 dB
(A, 20 kHz LPF)
DVD, TV/SAT, MD,
VIDEO3 (Optical)
S/N: 100 dB
(A, 20 kHz LPF)
MD/TAPE (REC OUT),
VIDEO 1, 2
(AUDIO OUT)
Voltage: 150 mV
Impedance: 2.2 kilohms
SUB WOOFER Voltage: 2 V
Impedance: 1 kilohms
Gain levels ±10 dB, 1 dB step
Area code Power requirements
CEL, CEK 230 V AC, 50/60 Hz
AU 240 V AC, 50 Hz
SP 220–230 V AC, 50/60 Hz
TW 110 V AC, 60 Hz
KR 220–230 V AC, 50/60 Hz
continued