2. Press the X key to write the adjusted value.
Adjustment and Connection Location:MAIN board
(See page 25)
Adjustment Method of Vl PWM Duty (L)
(item number: 764)
1. Connect a digital voltmeter to the AP913 (VLO) on the MAIN
board, and adjust
[VOL +] key (voltage up) or [VOL --] key
(voltage down) so that the voltage becomes 2.30 ± 0.01 V.
2. Press the X key to write the adjusted value.
Adjustment and Connection Location:MAIN board
(See page 25)
Adjustment Method of Vl PWM Duty (H)
(item number: 765)
1. Connect a digital voltmeter to the AP913 (VLO) on the MAIN
board, and adjust
[VOL +] key (voltage up) or [VOL --] key
(voltage down) so that the voltage becomes 2.55 ± 0.01 V.
2. Press the
X key to write the adjusted value.
Adjustment and Connection Location:MAIN board
(See page 25)
Adjustment Method of Vrec PWM Duty (L)
(item number: 766)
764 AD **
Set LCD display
**
: Adjusted value
digital
voltmete
r
MAIN board
AP913 (VLO)
AP602 (GND)
1. Connect a digital voltmeter to the TP (VREC) on the MAIN
board, and adjust [VOL +] key (voltage up) or [VOL --] key
(voltage down) so that the voltage becomes 1.13 ± 0.02 V.
2. Press the
X key to write the adjusted value.
Adjustment and Connection Location:MAIN board
(See page 25)
Adjustment Method of Vrec PWM Duty (H)
(item number: 767)
1. Connect a digital voltmeter to the TP (VREC) on the MAIN
board, and adjust
[VOL +] key (voltage up) or [VOL --] key
(voltage down) so that the voltage becomes 1.65 to 1.75 V.
2. Press the
X key to write the adjusted value.
Adjustment and Connection Location:MAIN board
(See page 25)
TEMPERATURE COREECTION
Adjustment Method of Temperature Correction
1. Select the manual mode of test mode, and set the item number
015 (see page 14).
2. Measure the ambient temperature.
3. Adjust with [VOL +], [VOL --] key so that the adjusted value
(hexadecimal value) becomes the ambient temperature.
(Initial value: 19h = 25 °C, Adjusting range: 80h to 7fh (–128
°C to +127 °C)
4. Press the X key to write the adjusted value.
digital
voltmeter
MAIN board
AP913 (VLO)
AP602 (GND)
765 AD **
Set LCD display
**
: Adjusted value
766 AD **
Set LCD display
**
: Adjusted value
digital
voltmeter
MAIN board
TP (VREC)
AP602 (GND)
767 AD **
Set LCD display
**
: Adjusted value
digital
voltmeter
MAIN board
TP (VREC)
AP602 (GND)
015 ###S**
Set LCD display
###
: Address
**
: Adjusted value