Sony MZ-N505 MiniDisc Player User Manual


 
22
MZ-N505
POWER SUPPLY MANUAL ADJUSTMENT
Adjustment Sequence
Adjustment must be done with the following steps.
1. Vc PWM Duty (L) adjustment (item number: 762)
r
2. Vc PWM Duty (H) adjustment (item number: 763)
r
3. Vl PWM Duty (L) adjustment (item number: 764)
r
4. Vl PWM Duty (H) adjustment (item number: 765)
r
5. Vrec PWM Duty (L) adjustment (item number: 766)
r
6. Vrec PWM Duty (H) adjustment (item number: 767)
Setting Method of Power Supply Manual Adjustment
1. Make sure that the power supply voltage is 3V.
2. Select the manual mode of the test mode (see page 14).
3. Set item number.
Adjustment Method of Vc PWM Duty (L)
(item number: 762)
1. Connect a digital voltmeter to the AP912 (VCO) on the MAIN
board, and adjust
[VOL +] key (voltage up) or [VOL --] key (volt-
age down) so that the voltage becomes 2.40 ± 0.05 V.
2. Press the X key to write the adjusted value.
Adjustment and Connection Location:MAIN board
(See page 25)
Adjustment Method of Vc PWM Duty (H)
(item number: 763)
1. Connect a digital voltmeter to the AP912 (VCO) on the MAIN
board, and adjust
[VOL +] key (voltage up) or [VOL --] key
(voltage down) so that the voltage becomes 2.50 ± 0.05 V.
873 ###S**
Set LCD display
###
: Address
**
: Adjusted value
874 ###S**
Set LCD display
###
: Address
**
: Adjusted value
762 AD **
Set LCD display
**
: Adjusted value
digital
voltmete
r
MAIN board
AP912 (VCO)
AP602 (GND)
763 AD **
Set LCD display
**
: Adjusted value
digital
voltmete
r
MAIN board
AP912 (VCO)
AP602 (GND)
49) Select manual mode of the test mode, and set item number
871 (see page 14).
50) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
CA.
51) Press the X key to write the adjusted value.
52) Select manual mode of the test mode, and set item number
872 (see page 14).
53) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
2D.
54) Press the X key to write the adjusted value.
55) Select manual mode of the test mode, and set item number
873 (see page 14).
56) Adjust with the
[VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
BB.
57) Press the X key to write the adjusted value.
58) Select manual mode of the test mode, and set item number
874 (see page 14).
59) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
05.
60) Press the X key to write the adjusted value.
871 ###S**
Set LCD display
###
: Address
**
: Adjusted value
872 ###S**
Set LCD display
###
: Address
**
: Adjusted value